Marine Systems Corporation
USS Firebolt (PC-10) is the 10th member of the Cyclone-class of coastal patrol boats
 




berths.jpg (46598 bytes)

LWMB Find Number Coding Typical Sheet 3C of ARR Drawing

Berth Curtain Size Find Number & Height Chart 12-24-20

Intended Use: In Crew and Troop Berthing Spaces

Hull Type Drawing Number: 804-5959312

National Stock Number: None

Type Style Size – millimeters, (inches)
Mattress Clearance Length Width Height*
Size 1 Size 2 Size 3
I 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 2,140 (84-1/4)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 2,290 (90-1/4)
II 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,970 (77-3/4)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 2,130 (83-3/4
III 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,780 (70-1/4)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,940 (76-1/4)
IV 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,780 (70)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,930 (76)
V 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 2,310 (91)
VI 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,440 (56-3/4)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,540 (60-3/4)
VII 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,250 (49-1/4)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,350 (53-1/4)
VIII 1 460 (18) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,240 (49)
2 510 (20) 1,920 (75-3/4) 2,010 (79-1/4) 2,110 (83-1/4) 700 (27-3/4) 1,350 (53)

*Height is measured from the top of the Subbase.

Principal Material: Aluminum  
REMARKS: ORDER OPTIONS:
Berths are designed to accommodate following mattresses in accordance with specification MIL-M-18351 (see 1D-1 when ordering mattresses.)

Size 1 Berth: Type I, Size 1 mattress

Size 2 Berth: Type I, Size 2 mattress

Size 3 Berth: Type I, Size 3 mattress

Mattress clearance is measured from top of mattress to underside of berth or locker over or to top of berth enclosure for upper berth.

Whenever a berth is provided without a locker under, a locker of equal volume shall be provided.

Ordering information must include following:

Type, style, size, and Hull Type Drawing Number.

Units can be ordered without back and panels to save weight.

Fan units.

Curtains and track see sheet B-2B-3.

 

Return to Top